Most international valve standards will demand the valve to NOT be exposed to high clamping force prior to the increase of testing pressure – a requirement hardly possible to be achieved with hydraulic clamping. Since more than 40 years, METRUS valve test benches are equipped with our superior automatic seal head technology. Those seal heads directly convert test fluid pressure into clamping pressure, ensuring a smooth and linear clamping force increase along with the increase of test fluid pressure.

Features

 
 Clamping range: DN15-DN400 1/2“-16“ Clamping force: 50 tons
Way of clamping: hydraulic clamping system with 3 and 2 claws (alternatively) Test fluid: Gas/air (external supply)
Pressure piping: PN 600 bar stainless steel Stainless steel control panel
Anodized, chemical resistant front panel Bubble counter + rubber plugs up to DN 100
Safety locking – prevents opening of clamping unit when system is pressurized. Gauge quick connection for tool free change of gauges
METRUS Precision valves

Options
 
Water testing up to 600 bar with test fl uid separation – separate measuring system, separate needle valves, st. steel drip pan Gauge turret for 4+1 gauges
Closed water circuit – 2 chamber stainless steel tank, fi lling pump, maintenance free evacuation system Safety cabinet for clamping unit
Bladder accumulator for water testing CRS with panel PC
Internal high pressure air generation via booster up to 400 bar. ESD Emergency Shut Off

Specifications


 

 Inquiry - SV 50/400 E